FET Transistor’s Static Parameters Tester

That’s my Bachelor’s qualification work.

Measured parameters:

1. Leakage drain current (GOST 20398.8-74; GOST 20398.10-80)

Drain-Source Voltage Range:

  • 0 … 20V, load current up to 1000mA;
  • 20 … 200V, load current up to 50mA;
  • 200 … 650V, load current up to 10mA.

Measurement ranges:

  • 0 … 0.1 mA,
  • 0 … 1 mA,
  • 0 … 10 mA,
  • 0 … 100 mA,
  • 0 … 1000 mA;

2. Drain cutoff current (GOST 20398.12-80)

Drain-Source Voltage Range:

  • 0-20V, load current up to 1000mA;
  • 20-200V, load current up to 50mA;
  • 200-650V, load current up to 10mA.

Gate-Source voltage range: -30 … +30V.

Measurement ranges:

  • 0…0.1 mA,
  • 0…1 mA,
  • 0…10 mA,
  • 0…100 mA,
  • 0…1000 mA.

3. Threshold voltage and cutoff voltage (GOST 20398.7-74)

Drain-Source voltage range: 1 … 20V.

Measurement range: -30 … +30V.

The boundary (threshold) value of the drain current: 0.01…1000 mA.

4. Gate Leakage Current (GOST 20398.6-74)

Gate voltage: -30… +30V.

Measurement ranges:

  • 0 … 2.5nA,
  • 0 … 25 nA,
  • 0 … 250 nA,
  • 0 … 2.5 μA.

5. Forward transconductance (GOST 20398.9-80, GOST 20398.3-74)

Drain-source voltage ranges:

  • 0-20V, Measured current limits 0.01 … 1000 mA (5 ranges);
  • 0-30V, Measured current limits 0 … 25A (2 ranges).

Gate-Source voltage range: -30 … +30V.

6. Active component of output conductivity (GOST 20398.4-74)

Drain-source voltage range: 0 … 20V.

Current measurement limits: 0.01 ÷ 1000 mA (5 ranges).

Gate-Source voltage range: -30 … +30V.

7. Drain-to-Source Resistance (GOST 20398.13-80)

Drain-Source current: 0.01 … 50A.

Gate-Source voltage range: -30 … +30V.

Measurement range: 0,002 … 500 Ohm.

8. Forward voltage of parasitic diode

Source-Drain current: 0.01 … 5A.

Measurement range: 0.01 … 5V.

View Presentation